Quantcast

Graft Distortion After Endovascular Repair of Abdominal Aortic Aneurysm: Association with Sac Morphology and Mid-Term Complications

Research paper by Derek Alan Gould, Richard David Edwards, Richard Gregory McWilliams, Peter Christopher Rowlands, Janis Martin, Donagh White, Simon Fear, Ali Bakran, John Brennan, Geoffrey Gilling-Smith, Peter Lyon Harris

Indexed on: 15 Jul '00Published on: 15 Jul '00Published in: CardioVascular and Interventional Radiology



Abstract

Purpose: To investigate the incidence, significance, and mechanism of stent-graft distortion after endovascular repair (EVR) of abdominal aortic aneurysm.Methods: EVR of abdominal aortic aneurysm was performed in 51 cases (49 modular, bifurcated; 2 tube). Thirty-two patients were followed for 6 or more months and had equivalent baseline and follow-up images which could be used to determine changes in graft configuration. Sac dimensions were measured using computed tomographic (CT) images and graft-related complications were recorded.Results: Amongst 32 patients evaluated on follow-up, there was graft distortion in 24. Distorted grafts were significantly (p= 0.002) associated with sac diameter reduction (mean 5 mm) and sac length reduction (mean 8.1 mm). All graft-related complications occurred in the limbs of eight distorted grafts, with a mean reduction of sac length in this group of 7.8 mm on reformatted CT images.Conclusion: There was a highly significant association between graft distortion and limb complications, and reduced sac dimensions.

More like this: