Autotrophic ammonia removal from landfill leachate in anaerobic membrane bioreactor.

Research paper by S S Suneethi, Kurian K Joseph

Indexed on: 13 Mar '14Published on: 13 Mar '14Published in: Environmental technology



Abstract

Anaerobic ammonium oxidation (ANAMMOX) process, an advanced biological nitrogen removal, removes ammonia using nitrite as the electron acceptor without oxygen. In this paper, ANAMMOX process was adopted for removing NH4+-N from landfill leachate having low COD using anaerobic membrane bioreactor (AnMBR). The AnMBR was optimized for nitrogen loading rate (NLR) varying from 0.025 to 5 kg NH4+-N/m3/d with hydraulic retention time (HRT) ranging from 1 to 3d. NH4+-N removal efficacy of 85.13 +/- 9.67% with the mean nitrogen removal rate of 5.54 +/- 0.63 kg NH4+-N/m3/d was achieved with NLR of 6.51 +/- 0.20kg NH4+-N/m3/d at 1.5 d HRT. The nitrogen transformation intermediates in the form of hydrazine (N2H4) and hydroxylamine (NH2OH) were 0.008 +/- 0.005 and 0.006 +/- 0.001 mg/l, respectively, indicating co-existence of aerobic ammonia oxidizers and ANAMMOX. The free ammonia (NH3) and free nitrous acid (HNO2) concentrations were 26.61 +/- 16.54 mg/l and (1.66 +/- 0.95) x 10(-5) mg/l, preventing NO2(-)-N oxidation to NO3(-)-N enabling sustained NH4+-N removal.